E-Series, it’s Smart it’s Easy.
Introducing the next generation of pacemakers.
Vitatron’s top-of-the-range G-series is built on the success of a company that’s dedicated to leading-edge technology without ever compromising the service, relationship and responsiveness you’ve experienced for over 50 years.
Diagnose, Prevent and Manage
The Ε-series offers an array of diagnostics, data and therapy for early detection, prevention and ongoing management of atrial arrhythmias.
Reduced Ventricular Pacing + (RVP+)
The new standard of care in pacing is to reduce unnecessary right ventricular pacing to a minimum.
Unnecessary RV pacing increases the risk of atrial fibrillation, heart failure hospitalization (HFH) and mortality.
Every incremental 1% of unnecessary RV pacing increases the risk of AF by 1% and the risk of HFH by 5.4%.
RVP+ reduces unnecessary RV pacing to less than 20%
- Continuously searches for natural intrinsic conduction
- Quickly optimizes AV delays relative to changes in patient PR intervals
- Allows AV delay to be extended up to 600 ms, thus maximizing conduction.
Smarter Rate Response
Dual slope rate response allows for independent customization of rate response for activities ranging from daily living to high exertion.
Rate Profile Optimization
Analyses the activity of the patient and customizes the rate response set points and target rates to achieve appropriate rate support of both high exertion activities and activities of daily life.
Ventricular Output Management improves patient safety and increases device longevity
Output Management
- Regularly measures thresholds and adapts pacing outputs to a safe level, even during changes in patient conditions – completely automatically.
- Proven safe, simple and accurate.
- Provides long-term threshold trends.
- Actively manages battery drain.
E-Series longevity is increased by more than 8% with output management and RVP+
Your patient’s device is automatically checked every day for:
- Lead impedance
- Battery status
- Ventricular threshold evaluation
Cardiac Dashboard II simplifies clinic follow-up, showing the full picture on a single screen.
Patient information includes:
- Clinical areas of concern
- A quick AT/AF summary
- Pacing/sensing data
Device information includes:
- Longevity status
- Thresholds
- Impedance
- Sensing data

E60 DR Dual Chamber
Click at photo
for detailed specifications
about E60DR

E50 D Dual Chamber
Click at photo
for detailed specifications
about E50DR

E10 S Single Chamber
Click at photo
for detailed specifications
about E60DR